
GlucoseCalibration
The LabChart 8 Glucose Calibration extension provides the ability to calibrate the new HD-XG implantable glucose telemeter from DSI in conjunction with the ADInstruments Biopotential Telemetry System.
v1.0.1400
Bu yazılım MirrorNest üzerinde barındırılmıyor — daha fazla bilgi için yazılımlarımız nereden geliyor sayfasına bakın. Yukarıdaki düğme doğrudan resmi sağlayıcıya götürür.
Hakkında
GlucoseCalibration is a Windows software extension for calibrating the HD-XG implantable glucose telemeter from DSI. It is designed to work with the ADInstruments Biopotential Telemetry System and LabChart 8. The product is intended for users who need to perform this calibration within that equipment and software setup.
Its central purpose is to connect the calibration process for the HD-XG telemeter with the LabChart 8 environment. The available information identifies calibration as its function, but does not specify additional analysis, recording, or reporting tools. Its use therefore depends on having the relevant DSI telemeter and the compatible ADInstruments telemetry system.
GlucoseCalibration fits the Windows category because Windows is its listed platform. It is best understood as a specialized extension rather than a general glucose-monitoring application. The software’s role is tied to a particular implantable device and telemetry workflow.
The license for GlucoseCalibration is unknown, so MirrorNest does not establish whether it is free, paid, or subject to separate terms. MirrorNest links directly to the official release instead of hosting a mirrored copy. Readers should obtain the software through that official release and review its licensing and compatibility information there.
Mimari: x86
v1.0.1400 sürümündeki yenilikler
- Fixed a bug where calibration was being applied at the highest sample rate of the document instead of the sample rate of the glucose channel. - Glucose Calibration data is not recoverable from in the event of a LabChart crash. Known Issues - Event markers for calibration points may not appear sometimes and at all in the first sampling record. Refresh the chart view or reload the document to ensure the data and event markers are drawn correctly. - Using a temperature channel with Out Of Range data values may caused unexpected results when used as the temperature compensation source channel for a glucose calibration.
İncelemeler
Henüz inceleme yok — ilk siz olun.
Sistem Araçları kategorisinde daha fazlası
Connect
Create customizable, reusable, and secure virtual experiences, as engaging as real-life interactions with Adobe Connect 12
1History
All your history in one file.
MSI
Create customizable, reusable, and secure virtual experiences, as engaging as real-life interactions with Adobe Connect 12
CreativeCloud
Get all 20+ creative apps including Photoshop, Illustrator, and Premiere Pro.
check-mk agent
The Windows Agent for OMD
check_mk_agent
check_mk_agent