GlucoseCalibration1.0.1400
The LabChart 8 Glucose Calibration extension provides the ability to calibrate the new HD-XG implantable glucose telemeter from DSI in conjunction with the ADInstruments Biopotential Telemetry System.
v1.0.1400
This title isn't mirrored on MirrorNest — see how we source software for why. The button above goes straight to the official publisher.
About
GlucoseCalibration lets researchers calibrate DSI’s HD-XG implantable glucose telemeter within LabChart 8, connecting calibration measurements to the telemetry workflow. Published by ADInstruments, it functions as an extension for the ADInstruments Biopotential Telemetry System rather than as a general glucose-monitoring program. Its purpose is to bring HD-XG calibration into the LabChart environment used for recording and analyzing the experiment.
Use requires the compatible DSI telemeter, the ADInstruments Biopotential Telemetry System, and LabChart 8. It is intended for researchers performing calibration within this specific implantable-device and telemetry setup. Because its operation is tied to one telemeter and platform, it is a specialized laboratory extension rather than a standalone glucose application.
GlucoseCalibration runs on Windows systems with x86 architecture. The current version is 1.0.1400, and it fixes a defect that could apply calibration according to the document’s highest sample rate instead of the sample rate assigned to the glucose channel. Calibration data cannot be recovered if LabChart crashes, so a crash can permanently affect that information.
Calibration-point event markers may sometimes be missing, including being absent from the first sampling record; refreshing the chart view or reloading the document redraws the data and markers correctly. A temperature channel containing out-of-range values can also produce unexpected results when selected as the temperature-compensation source for glucose calibration.
Architecture: x86
What's new in v1.0.1400
- Fixed a bug where calibration was being applied at the highest sample rate of the document instead of the sample rate of the glucose channel. - Glucose Calibration data is not recoverable from in the event of a LabChart crash. Known Issues - Event markers for calibration points may not appear sometimes and at all in the first sampling record. Refresh the chart view or reload the document to ensure the data and event markers are drawn correctly. - Using a temperature channel with Out Of Range data values may caused unexpected results when used as the temperature compensation source channel for a glucose calibration.
Details
Does this still work for you?
Reviews
No reviews yet — be the first.
GlucoseCalibration alternatives
dotMemory Unit Standalone Launcher
Effective memory usage in .NET applications with dotMemory Unit
GamebarHandler
Gets rid of those pesky 'open ms-gamebar' and 'open ms-gamingoverlay' popups.
ShareX
ShareX is a free and open-source application that enables users to capture or record any area of their screen with a single keystroke. It also supports uploading images, text, and various file types to a wide range of destinations.
cerebro-es (Install)
elasticsearch web admin tool
CPUID CPU-Z
System information software
Vantage
Vantage